Suzhou Kiande Electric Co.,Ltd.

Specialized in intelligent production equipment in electrical field!

Manufacturer from China
Active Member
5 Years
Home / Products / Busbar Machine /

Unilateral Manual Irregular Busduct Inspection Machine

Contact Now
Suzhou Kiande Electric Co.,Ltd.
City:suzhou
Province/State:jiangsu
Country/Region:china
Contact Person:MsTina
Contact Now

Unilateral Manual Irregular Busduct Inspection Machine

Ask Latest Price
Video Channel
Model :KD-JCX/M-6
Busbar Height :100mm~650mm
Busbar Length :500mm~3000mm
Power :380~415VAC 50~60Hz 3kW
Grounding Test :0~25A
Insulation Test :1~1000V
High Voltage Withstanding Test :0~5000V
Servo Nos :L6200mm*W800mm*H800mm
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Unilateral Manual Irregular Busduct Inspection Machine

Function introduction

Manual Busbar Inspection Line is mainly used for inspecting short straight busbar, elbow busbar, terminal busbar and etc.. It’s composed of two parts: fixture positioning and main inspection instruments. Fixture positioning part is operated manually while inspection instruments will test the busbar and generate the report automatically.

Unilateral Manual Irregular Busduct Inspection Machine

Equipment data on Manual busbar inspection line

No. Parameters
Model KD-JCX/M-6
Busbar Height 100mm~650mm
Busbar Length 500mm~3000mm
Suitable Busbar Type Irregular busbar
Position Type Unilateral

Printing System

Bar code printing/ Report printing( optional)

High Voltage Withstanding Test

0~5000V
Insulation Test 1~1000V
Grounding Test 0~25A

Power

380~415VAC 50~60Hz 3kW

Equipment Dimension

L6200mm*W800mm*H800mm

Feature

Customized
testing report can be saved, printed on site and recorded remotely. Its format can be set according to customer’s requirements.

Fuction

HV withstanding test, insulation resistance test and grounding test

Inquiry Cart 0